Icon Close
  • ANGIODROID THE CO2 INJECTOR

    ANGIODROID THE CO2 INJECTOR

    The “ANGIODROID THE CO2 INJECTOR” device allows the injection of carbon dioxide (CO2) into the vascular cavities, in order to carry out angiographic type examinations.

    CO2 acts as a medium of contrast during an angiographic examination.

    INDICATIONS

    Angiodroid The CO 2 Injector is the first and only patented device on the international market that allo

    Read more

    market that allows injections of medical CO₂ into blood vessels with a precise volume and at a given pressure, and above all without contamination of the air. Acting as a perfectly biocompatible contrast agent, carbon dioxide guarantees both high quality radiological images and patient safety when performing an angiographic examination.

    Angiodroid The CO 2 injector: Where? When? Why? How?

    The injector has three main areas of application:

    • Interventional radiology

    • Vascular surgery
    • Interventional cardiology

    CO₂ injection can be performed in the following body areas:

    • Abdominal aorta

    • lower limbs
    • diabetic foot
    • Fistula hemodialysis
    • Renal arteries
    • Pelvic arteries
    • Hepatic arteries
    • Peripheral venous system

    Since CO₂ is a safe and effective option in almost all of the above cases, the use of Angiodroid is indicated for all patients undergoing peripheral angiography, especially for diabetic patients and absolutely necessary for patients allergic to CO₂. iodine or suffering from kidney disease, which could be aggravated by iodinated contrast material, causing contrast-induced nephropathy.

    The Injector is fully automatic, the operator only has to connect the catheter to the injection line (supplied with the product) and choose from the predefined parameters studied for each district to be analyzed (customizable according to the situation if necessary).

    product details

    The injection can be carried out both via the touch screen panel and the wireless remote control supplied with the injector: in the second case, the operator can also be in the other room (at a maximum distance of 15 meters) during angiography, avoiding a great deal of X-ray exposure.

    Arc synchronization is also possible thanks to the cable provided by Angiodroid, compatible with Philips and Ziehm Angiosystems.

    What guarantees the best possible performance is the integrated pressure sensor which constantly monitors the injector.

    Security

    CO₂ is an odorless, colorless and invisible gas, which is why it is important not to let it mix with the ambient air during the injection, in order to avoid an embolism. The Injector ensures the use of just "pure" medical CO₂ thanks to the one-way valve at the end of the injection line (and the automatic washing of the catheter carried out as soon as it is connected to the device).

    Speed

    Thanks to Angiodroid, the injection is quick and easy: after setting the parameters, the system will automatically load the desired dose to be used and the external LEDs will signal the status of the injector to know when to start the procedure.

    Simplicity

    Ease of use starts with the ergonomic design of the device, which is easily moved from room to room thanks to its four wheels (and relative brakes).

    Moreover, when using the injector, the operator can not only choose preset dedicated parameters, but also save his custom values ​​and set the automatic injection repeat, which will only take 30 seconds thanks to the Fast Automatic Reload function.

    The Injector is in fact almost completely independent of the operator, due to its automatic procedures: the user will only have to switch on the device, connect the catheter and start the injection with the desired parameters.

    This equipment is distributed by Promamec Maroc.